A1000 AC Drives – Input, Output, and Keypad Options

A1000 600V AC DriveA1000 600V AC Variable Frequency Drive

1-30 Horsepower
The Drive for the Future . . . Today

 

Input, Output, and Keypad Options for A1000 600V Drive

This array of option cards can extend the flexibility and adaptability of Yaskawa AC drives. These options may be factory installed or field installed.

Compare this drive’s Input Output Options to other Yaskawa AC Drives.

Analog Inputs Option Card # & Mounting Location Installation Manual
(13 Bit + Sign) – Provides interface of 3 high resolution analog inputs to the drive. Signal levels (individually selectable): 0 to +/- 10 VDC (20kOhm) or 4 to 20mA (500 ohm). Input resolution: Voltage (1/8192), Current (1/6654). AI-A3
CN5-A
TOBPC73060038

 

Digital Inputs Option Card # & Mounting Location Installation Manual
(8, 12, or 16 Bit) – Provides interface of a 16 bit digital input (binary or BCD) to the drive. Signal type is selectable by parameter setting for:
Binary 16 bit, 4 digit BCD
Binary 12 bit, 3 digit BCD
Binary 8 bit, 2 digit BCD
DI-A3
CN5-A
TOBPC73060039

 

Analog Outputs Option Card # & Mounting Location Installation Manual
(11 Bit + Sign) – Provides 2 signals for remote metering of any two of the drive’s “U1” monitors. Additive to the two standard analog outputs. Signal level: 0 to +/- 10 VDC (20kOhm). AO-A3
CN5-A, B, or C
TOBPC73060040

 

Digital Outputs Option Card # & Mounting Location Installation Manual
(8 Channels) – Provides 8 additional digital outputs for use in monitoring the status outputs of the drive. Signal levels: 2 channels of Form A, 250 VAC, 30 VDC, 1 A and 6 channels of PHC, 48 VDC, 50 mADC, Shared Common. DO-A3
CN5-A
TOBPC73060041

 

Encoder (PG) Feedback Option Card # & Mounting Location Installation Manual
Single Encoder – Line Driver – Provides velocity and direction feedback from an encoder. Primarily used for motor speed feedback in closed loop flux vector control. A 5 VDC buffered output is also included. Signal levels: 5 or 12 VDC differential line driver with compliments, maximum input frequency of 300 kHz, phases A and B (Z required with some custom software). PG-X3
CN5-C or B
TOBPC73060037
Single Encoder – Open Collector – This option provides velocity and direction feedback from an encoder. This is primarily used for motor speed feedback in closed loop flux vector control. A 24DC buffered output (open collector) is also included. 32 kHz maximum input frequency. PG-B3
CN5-C or B
TOBPC73060036

 

Keypad Options Option Card # & Mounting Location Installation Guide & Technical Manual
The LED Operator allows the drive to be operated from a remote location up to 3-meters.JVOP-182 Kit Contents:
Qty Description
1 LED Operator
1 Installation Manual (TOBPC73060035)Note: This option requires Installation Set A (EZZ020642A) for panel or door mounting and Remote Operator Cable (UWR0051 or UWR0052), each sold separately.
JVOP-182
RJ-45 Keypad
Port
TOBPC73060035

 

USB Copy Unit (Y-Stick) Model Number & Mounting Location Installation Guide & Technical Manual
USB Copy Unit (Y-Stick)The USB Copy Unit (Y-Stick) allows the drive to connect to the USB port on a PC. It can read, copy and verify drive parameter settings from one drive to another like drive.JVOP-181 Kit Contents:
Qty Description
1 USB Copy Unit (Y-Stick)
1 1 ft USB Cable to connect PC to Y-Stick
1 3 ft Cable with RJ-45 connector on both ends to connect Y-Stick to drive
1 Technical Manual (TOBPC73060025)Driver: SP1824_001
Note: This driver is required to be installed on the PC before the Y-stick can be used.
JVOP-181
RJ-45 Keypad
Port
IG.V1000.01
TOBPC73060025
CopyUnitManager PC Software
CopyUnitManager is a PC software program that works along with the Y-Stick Copy Unit (JVOP-181) that allows the user to transfer and save parameter files from the Y-Stick to a PC and vice versa. The CopyUnitManager software can be used to save parameter files for a variety of drive sizes and parameter configurations. Simply configure the drive parameters, transfer them to the Y-Stick Copy Unit, then save them to your PC for backup or for quickly downloading multiple drives.> Download Software (5.9MB)System Requirements

  • PC: PC/AT DOS/V Compatible machine
  • CPU: Pentium II Processor 2GHz, 3GHz or more recommended
  • Memory: 512MB, 1GB or more recommended
  • Hard Disk Capacity: More than 400MB
  • Operating System: WindowsXP SP2, Windows2000 SP4
UL Rated Remote Operator Kit
This option is used to extend the existing Digital Operator to the wall of a separately priced, oversized UL Type 1, 3R, 4, 4X, or 12 enclosure (IPX6 environment). Price includes a faceplate bezel with digital operator brackets and membrane to cover the operator cutout in the enclosure door, a 3-foot cable, a 10-foot cable, and a 1:1 template for cutting the necessary cutouts in the enclosure. Keypad can be removed after kit installation. Designed for use with the LCD Operator JVOP-180 or the LED Operator JVOP-182 sold separately.
UUX000526 (Blank Membrane)
Connects to RJ45 port and mounts to enclosure door.
TOEPYEAOPT02
UUX000527 (Yaskawa Logo Membrane)
Connects to RJ45 port and mounts to enclosure door.

 
Copyright © 2010 Yaskawa Electric America, Inc. All Rights Reserved.